WILDFIRE DETECTION · CAMERA PLANNING

    Plan wildfire detection cameras before the first mast goes up

    See which slopes a camera on a hilltop mast covers across terrain and forest, how large the smoke is in the picture at 13 km, and whether the mast holds in the design wind.

    Watch the film
    Smoke rising from a forest fire on a wooded mountain slope, in the planner's 3D view.

    FILM · 3:29

    Spotting wildfire smoke 13 km away

    Two 40 m masts in the Karkonosze and Jizera Mountains and a fire in the valley between them. Every number in the film comes from the planner.

    The film plays from YouTube, with audio in 7 languages and subtitles in 33.

    FIVE CHECKS · ONE PROJECT

    From the map to the mast

    NO.01

    Line of sight over terrain and forest

    Each camera sweeps up to 50 km around it, over elevation data and the height of the forest canopy. Green ground is seen, red ground is hidden behind terrain or treetops.

    Planner map of mountains with a camera's line of sight: visible ground in green, ground hidden behind terrain or treetops in red.
    From the 40 m mast at Kamienica, terrain and treetops hide 67% of the ground in reach.
    NO.02

    Terrain profile to any point

    Click any spot and the profile draws the sightline over the ground and the treetops, with the earth's curvature and refraction taken into account, and says how tall something there must be to show.

    Terrain profile from the Kamienica mast toward the fire: the sightline runs into treetops at 6.12 km.
    Kamienica to the fire, 8.36 km: treetops at 6.12 km hide 50 m of smoke, which would have to rise 310 m to show.
    NO.03

    The picture at every focal length

    The camera's view is built from the manufacturer's lens data. The Hikvision DS-2TD8167-230ZG2F/W in the film zooms from 24.33° to 0.41°: at 13.2 km the frame is 94.5 m wide and a 35 m smoke trail is 711 pixels across.

    View from the Smogornia mast at 24.33°: forested slopes and a valley under scattered clouds.
    Smogornia at 24.33°: the fire is 13.2 km away, somewhere in this valley.
    The same camera at 0.41°: a column of smoke over the forest at the edge of a village.
    At 0.41°, the 1000 mm end of the lens, the smoke fills the frame.
    NO.04

    Thermal through rain

    In light rain of 2.5 mm/h visibility drops to 5.9 km and the visible channel shows grey. The 640 × 512 thermal channel still sees the fire at 13.2 km: 14 × 27 pixels, 59 times brighter than ground at 20 °C.

    Visible channel in light rain: a uniform grey picture with rain streaks.
    Visible light in light rain: nothing to see at 13.2 km.
    Thermal channel in the same rain: dark forest and a small bright spot where the fire burns.
    Thermal, same rain, same moment: the fire is there.
    NO.05

    The mast that carries it

    Mast height, the camera at the top and the guys belong to the same project. The validator checks the pole in the design wind and proposes guys: a 40 m tube at 120% of its strength drops to 23% with 3 × Ø8 mm at 19.6 m and 3 × Ø8 mm at 39.2 m.

    A 40 m guyed mast over pine forest on a mountain top, in the planner's 3D view.
    The 40 m mast at Smogornia with guys on two levels.
    System validator report: a 40 m pole at 120% of its strength in the design wind, with the guys it needs.
    The validator names the overload and the guys that fix it.

    WHAT GOES INTO THE PLAN

    The data behind every check

    • Elevation: national surveys where available, EU-DEM 25 m and global terrain tiles of about 30 m further out.
    • Forest: every forest from OpenStreetMap within 50 km, with the canopy height you set.
    • Smoke: a smoke column with its height and drift, and a flame front for the thermal picture.
    • Cameras: lens, sensor and thermal channel from the manufacturer's datasheet.
    • Weather: scattered clouds, overcast and rain, with visibility from the rain rate.

    Line of sight over terrain and the 3D camera view are in the Pro plan. See plans

    Questions

    How far can a wildfire detection camera see smoke?

    Terrain and forest decide it more than the lens. With a 1000 mm lens the frame at 13.2 km is 94.5 m wide, so 35 m of smoke is large in the picture, but a ridge or treetops in between hide it completely. The line of sight check shows which ground each camera can actually see.

    How tall should a fire-watch mast be?

    Tall enough to see over the forest around it and over the ridges in between. In the film, two 40 m masts in forest with a 20 m canopy gave opposite answers: one saw the smoke 13.2 km away, the other missed it at 8.36 km because treetops on a plateau were in the way.

    Does a thermal camera see a wildfire in rain?

    In light rain, yes, even at long range. In the film the visible channel shows grey at 5.9 km visibility, while the thermal channel shows the fire 13.2 km away. Smoke is almost transparent in long-wave infrared, so thermal sees the flames rather than the smoke.

    Which plan includes these checks?

    Line of sight over terrain and the 3D camera view are in the Pro plan. Placing cameras on the map works on every plan, within its camera limit.

    Plan your first fire-watch camera

    Find the site, add the forest and a mast, and check what the camera can see before anything is built.

    Perimeter intrusion design